PTU288-1 and Accessories  
• Optically and acoustically signals  
the events of a fire detection or  
extinguishing control panel  
• Actuation of up to 144 LED pairs,  
single LEDs or relays  
• Single or summary indication  
parameterisable  
• Connection to the INFO bus  
• Easy parameterisation by means of  
PC software PARSOFT  
Description  
The Remote Tableau Drive Unit PTU288-1 allows to op- Furthermore, the PTU288 has 5 freely parameterisable  
tically signal events of a Fire Detection Control Panel control inputs.  
Series BC216 or BC016, or of an Extinguishing Control  
Panel Series LC216, on an optional synoptic remote The remote tableau drive unit is connected to the fire  
tableau. In addition, a built-in buzzer signals the alarm detection control panel via the INFO bus. Auxiliary mo-  
or fault condition of the control panel.  
dules are not needed for connection to Control Panels  
Series BC216. A Serial Interface Module SIM016-3 is  
Up to 3 LED Display Fields LAB48 or LED Connection necessary for connecting the PTU288 to a Fire Detec-  
Modules LAM48-1 can be connected to the remote tab- tion Control Panel Series BC016.  
leau drive unit in any combination.  
In accordance to the parameterisation, the LEDs can be The PC software PARSOFT is used to parameterise the  
used to display the conditions of detectors, detector zo- remote tableau drive unit via the USB interface.  
nes, actuations, actuation elements, alarming devices,  
transmitting devices, extinguishing systems or flooding The componentry is prepared for direct installation into  
zones as well as the most important system conditions the LED Display Tableau LAT288-1 or LAT288-1CE. The  
of the fire detection control panel (e.g., summary alarm, componentry can also be mounted in any housing in the  
fault condition or disablement condition). If needed, it is LST standard grid, using the supplied mounting parts.  
also possible to combine several events into a summary  
display.  
Specifications  
Operating voltage  
Current consumption at 24V  
Ambient temperature  
Dimensions L × W × H  
Weight  
15 – 31VDC  
typ. 15mA (without LED modules)  
-20°C to +60°C  
150 × 75 × 20 (mm)  
76g  
Order number  
252012  
Order name  
Remote Tableau Drive Unit PTU288-1  
Building Safety. Building Security.  
A
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27  
PTU288-1_DBL_LST_EN_0804.PDF • PAGE 1  
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED  
 
LED Connection Cord  
The 2-wire connection cord serves to connect light – have to be actuated.  
emitting diodes or relays to the LED Connection Mo-  
dule LAM48-1. The cord is needed if other than the At one end of the cord there is a connector which fits  
pre-assembled LEDs are used, or if more than two Re- to the pin connector of the LED Connection Module  
lay Modules RL58-1 or RL58-2 – which can be directly LAM48-1, and the other end of the cord is open.  
connected to the LED connection module via flat cable  
Specifications  
Line length  
2m  
Order number  
Order name  
259013  
Cord 2-Wire for LED Connection/10pcs. LED-LEITUNG-10  
Building Safety. Building Security.  
A
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27  
PTU288-1_DBL_LST_EN_0804.PDF • PAGE 3  
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED  
 

Krell Industries Stereo Amplifier KAV 150a User Manual
Leica Microscope Magnifier DM IRB User Manual
Liebherr Refrigerator 7084376 03 User Manual
Lightolier Indoor Furnishings XP1GVA232 User Manual
Magic Chef Blender MCBL5CG User Manual
Maxtor DVR HVR 04E User Manual
Maytag Refrigerator UKF8001AXX 200 User Manual
MB QUART Car Speaker RSC 213 User Manual
Meade Telescope NG User Manual
MicroNet Technology Switch SP624R User Manual